Home
Print
 

Calibration Solutions

 

LiquiCalTM

LiquiCal is a range of high performance liquid baths used for high precision temperature calibrations. The baths can be controlled via PC allowing for automated calibration and ramp control or as a stand alone unit. LiquiCal provides high accuracy along with a large immersion depth, high stability, fast temperature change and quiet run.

The models cover temperatures from -80°C to +300°C all having the same exterior dimensions, bath openings and liquid filling volume except for the micro baths (LiquiCal SM/HM) which are far smaller facilitating mobility.
 
Open online brochure
 

Complete Automated Solution
The LiquiCal baths can be integrated with Ellab Temperature Standard (ETS) and Valsuite Pro calibration and validation software for complete automated calibration and control. The software will control the ramp, stability time and automatically calibrate Ellab's data logging equipment.

A convenient overflow reservoir captures any excess fluid that results from fluid expansion. The bath's 15.9 L (4.2 gallon) tank can easily be emptied by drain when needed.

Liquids for LiquiCal baths
To obtain optimal temperature stability and homogeneity in the calibration zone liquids with the lowest possible viscosity (< 25 CST) are preferred. Ellab supplies a range of liquids in 3.8 L (1 gallon) containers covering the temperature range of -80°C to +300°C safely.

Type  Temperature
Ellab Low Temperature Liquid -80°C to +5°C
Ellab Standard Oil -30°C to +200°C
Ellab High Temperature Oil +80°C to +300°C

One Bath/One Oil - Concept
Using Ellab Standard Oil within a temperature range of -30°C to +150°C together with LiquiCal SL bath, you will be able to cover most validation applications, including:

· Sterilization using autoclaves and retorts.
· Pasteurization using plate heat exchangers.
· Testing using environmental chambers.
· Chilling using refrigerators.
· Storing in freezers.

Ellab Temperature Standard
Traceable ETS allows extremely accurate temperature calibration. ETS is available in 3 different versions and comes with calibration certificates traceable to NPL. The ValSuite Pro software with the ETS and the LiquiCal provides an automatic setup, which simplifies the calibration system and saves time.

ValSuite Pro Software
ValSuite Pro Software allows semi or full-automatic pre and post calibration of cable probes or wireless loggers. Using the intuitive menus all data necessary for software calibration is processed, generating offset values that are stored in the software. For TrackSense Pro wireless loggers and E-Val Flex intelligent cable probes a firmware calibration routine is recommended on a regular basis, and user alert can be programmed into the memory for smart handling.

Calibration Set-up
Ellab calibration software uses a point-to-point method and can handle multiple points using only interpolation. When choosing semi-automatic calibration only an ETS is connected. In a full-automatic calibration both the ETS and LiquiCal bath are in operation. The following performance criteria can be set:

· Maximum allowed calibration bath fluctuation band and time.
· Holding time.
· Max allowed temperature standard fluctuation.
· Maximum sensor temperature deviation and pass time.

All setup conditions and acceptance criteria together with actual values and deviations are shown in the calibration report.

Contact Ellab A/S
Contact