Operating Temperature |
5°C to 40°C/ 41°F to 104°F |
|
Operating Voltage |
5V External Adapter 100-240V AC, 50-60 Hz or USB |
|
Reader/Logger Communication |
Induction |
|
PC Interface |
USB |
|
Capacity |
1-4 Loggers at a Time |
|
Expansion |
1-3 Modules |
|
Expansion Capacity |
5-16 Loggers |
| Operating Temperature | 5°C to 40°C/ 41°F to 104°F |
| Operating Voltage | NA |
| Reader/Logger Communication | Induction |
| PC Interface | USB |
| Capacity | 1 Logger at a Time |
|
|
Pro X |
Pro |
Pro Basic |
|||||||
|
Operating Temperature |
-80 to +150°C |
-50 to +150°C |
-30 to +105°C |
|||||||
|
Operating Pressure* |
0 mbar to 10 bar abs. |
0 mbar to 10 bar abs. |
0 mbar to 10 bar abs. |
|||||||
|
Material |
316 Stainless Steel |
316 Stainless Steel |
316 Stainless Steel |
|||||||
|
Diameter |
25 mm. |
25 mm. |
25 mm. |
|||||||
|
Length |
44 mm. |
44 mm. |
44 mm. |
|||||||
|
Weight With Battery |
48 Grams |
48 Grams |
48 Grams |
|||||||
|
Memory Capacity |
60,000 Data Points |
60,000 Data Points |
60,000 Data Points |
|||||||
|
Minimum Sample Rate |
1 Second |
1 Second |
1 Second |
|||||||
|
Maximum Sample Rate |
24 Hours |
24 Hours |
24 Hours |
|||||||
|
Maximum Start Delay |
14 Days |
14 Days |
14 Days |
|||||||
|
Resolution |
0.007°C |
0.007°C |
0.007°C |
|||||||
|
Intrinsically Safe |
Ex II 1G Ex ia IIC T3 |
Ex II 1G Ex ia IIC T3 |
Ex II 1G Ex ia IIC T3 |
|||||||
|
Compliance |
CE |
CE |
CE |
|||||||
|
Sensor |
Interchangeable |
Interchangeable |
Interchangeable |
|||||||
|
Time Accuracy |
±5 Seconds Per 24 Hours |
±5 Seconds Per 24 Hours |
±5 Seconds Per 24 Hours |
|||||||
|
Operating Temperature |
-50°C to +150°C |
|
Battery Type |
Lithium |
|
Capacity: |
|
|
Temperature 1 Sensor |
1,000 Hours |
|
Temperature 2 Sensors |
500 Hours |
|
Pressure |
400 to 500 Hours |
|
RH% |
750 Hours |
|
Intrinsically Safe |
EEx ia IIC T3 |
|
Compliance |
CE, UL Listed |
|
Type |
Rigid SS Standard |
Rigid SS High |
|
Diameter |
2 mm / 3 mm |
3 mm |
|
Length |
From 10 mm |
From 150 mm |
|
Dimension of sensing element |
1.2 x 1.6 mm |
1.2 x 1.6 mm |
|
Position of measuring point: |
|
|
|
From round tip |
3 mm |
3 mm |
|
From sharp tip |
6 mm |
6 mm |
|
From conical tip |
8 mm |
8 mm |
|
Temperature measuring range |
-196°C to +150°C |
0 to +400°C |
|
Accuracy: |
|
|
|
Low -196 to -80°C |
± 0.5°C |
- |
|
Low -80 to -50°C |
± 0.3°C |
- |
|
Low -50 to -40°C |
± 0.2°C |
- |
|
Low -40 to -25°C |
± 0.1°C |
- |
|
Low -25 to 0°C |
± 0.05°C |
- |
|
Standard 0 to 100 °C |
± 0.05°C |
- |
|
Standard +100 to +140°C |
± 0.05°C |
- |
|
Standard +140 to +150°C |
± 0.05°C |
- |
|
High 0 to +400°C |
- |
± 0.5°C |
|
Sensor capacity |
1 or 2 |
1 |
|
Sensor response time: |
|
|
|
T-10% |
0.11 sec. / 0.22 sec. |
|
|
T-50% |
0.35 sec. / 0.72 sec. |
|
|
T-63% |
0.5 sec. / 1.00 sec. |
|
|
T-90% |
1.10 sec. / 2.00 sec. |
|
|
Pressure operating range |
0.001 mBar to 10 Bar ABS |
0.001 mBar to 10 Bar ABS |
| Type |
Semi Flexible SS Standard |
Semi Flexible SS High |
| Diameter |
1.5 mm / 2 mm / 3 mm |
2.0 mm / 2.5 mm |
| Length |
100 -1000 mm |
150 - 1000 mm |
| Dimension of sensing element |
0.8 x 3.0 mm / 1.2 x 1.6 mm / 1.2 x 1.6 mm |
1.2 x 1.6 mm |
| Position of measuring point: |
|
|
| From round tip |
3 mm |
3 mm |
| From sharp tip |
6 mm |
6 mm |
| From conical tip |
8 mm |
8 mm |
| Temperature measuring range |
-196°C to +150°C |
0 to +400°C |
| Accuracy: | ||
| Low -196 to -80°C |
± 0.5°C |
- |
| Low -80 to -50°C |
± 0.3°C |
- |
| Low -50 to -40°C |
± 0.2°C |
- |
| Low -40 to -25°C |
± 0.1°C |
- |
| Low -25 to 0°C |
± 0.1°C |
- |
| Standard 0 to 100°C |
± 0.1°C |
- |
| Standard +100 to +140°C |
± 0.1°C |
- |
| Standard +140 to +150°C |
± 0.1°C |
- |
| High 0 to +400°C |
- |
± 0.5°C |
| Sensor capacity | 1 or 2 | 1 or 2 |
| Sensor response time: | ||
| T-10% | - / 0.11 sec. / 0.22 sec. | - |
| T-50% | - / 0.35 sec. / 0.72 sec. | - |
| T-63% | 0.46 sec. / 0.41 sec. / 1.00 sec. | 1.46 sec. / 6.96 sec. |
| T-90% | 0.67 sec. / 0.81 sec. / 2.00 sec. | 2.87 sec. / 17.72 sec. |
| Pressure operating range | 0.001 mBar to 4 Bar ABS | 0.001 mBar to 4 Bar ABS |
|
Type |
Flexible Low |
Flexible Standard |
| Diameter |
1.2 mm |
1.8 mm |
| Length |
100 - 500 mm |
100 - 1000 mm |
| Dimension of sensing element |
0.8 x 3 mm |
1.2 x 1.6 mm |
| Position of measuring point: |
|
|
| From round tip |
3 mm |
3 mm |
| From sharp tip |
|
6 mm |
| From conical tip |
|
8 mm |
| Temperature measuring range |
-196°C to +100°C* |
-196°C to +140°C |
| Accuracy: | ||
| Low -196 to -80°C |
± 0.5°C |
± 0.5°C |
| Low -80 to -50°C |
± 0.3°C |
± 0.3°C |
| Low -50 to -40°C |
± 0.2°C |
± 0.2°C |
| Low -40 to -25°C |
± 0.1°C |
± 0.1°C |
| Low -25 to 0°C |
± 0.1°C |
± 0.1°C |
| Standard 0 to 100°C |
± 0.1°C |
± 0.1°C |
| Standard +100 to +140°C |
- |
± 0.1°C |
| Standard +140 to +150°C |
- |
- |
| High 0 to +400°C |
- |
- |
| Sensor capacity | 1, 2 or 4 | 1 or 2 |
| Sensor response time: | ||
| T-10% | - | - |
| T-50% | - | - |
| T-63% | 1.34 sec. | 2.16 sec. |
| T-90% | 2.55 sec. | 4.31 sec. |
| Pressure operating range | 0.001 mBar to 1 Bar ABS |
0.001 mBar to 4 Bar ABS |
| Pressure Sensor | |
| Material | Stainless Steel |
| Measuring Principal | Strain Gauge |
| Operating Temperature | 0 to +150°C |
| Operating Pressure | 10 mBar to 10 Bar Absolute |
| Measuring Range | 10 mBar to 6 Bar Absolute, Up To 7 Bar Can Be Ordered |
| Resolution | 1 mbar |
| Measuring Accuracy | ±0.25% Full Scale |
| General Sensor Specifications | |
| Material | Stainless Steel |
| Operating Temperature | 0 to +150°C |
| Sampling | 1 Sec. To 24 Hours Auto Start/Stop |
Pressure Sensor
Measuring Principal
Strain Gauge
Operating Pressure
10 mBar to 10 Bar Absolute
Measuring Range
10 mBar to 6 Bar Absolute, Up To 7 Bar Can Be Ordered
Resolution
1 mbar
Measuring Accuracy
±0.25% Full Scale
| Temperature Sensor | |
| Measuring Principal | External PT1000 |
| Length Of Sensing Element | 20 mm |
| Measuring Range | 0 to +150°C |
| Resolution | 0.012°C |
| Measuring Accuracy | ±0.05°C |
|
1. Stability Chambers* |
2. EtO/Stability |
3. EtO |
|
| RH Sensing Element: |
Capacitance |
Capacitance |
Capacitance |
| Temperature Sensing Element: |
RTD |
RTD |
RTD |
|
|
|
||
| Relative Humidity: | |||
|
Range (-40 to +80°C): |
0-100% |
0-95% |
0-100% |
|
Resolution: |
0.03% |
0.025% |
0.1% |
|
Repeatability: |
±0.1% |
|
±0.5% |
| Response Time (63% In Slowly Moving Air): |
8 Sec. |
6 Sec. |
50 Sec. |
|
Accuracy At 25°C Non-Condensing: |
|||
|
(10% to 90%): |
±2% |
±2% |
±2% |
|
|
|
||
| Temperature: | |||
| Range: |
0 to +85°C |
0 to +85°C |
0 to +85°C |
| Resolution: |
0.01°C |
0.012°C |
0.012°C |
| Repeatability: |
±0.1°C |
|
|
| Response Time: |
Max 30 Sec. |
Max 5 Sec. |
Max 30 Sec. |
| Accuracy: | |||
|
+5°C to +40°C |
±0.5°C |
±0.1 oC |
±0.1°C |
|
+40°C to +65°C |
±1.0°C |
±0.1 oC |
±0.1°C |
|
+65°C to +90°C |
±1.5°C |
±0.1 oC |
±0.1°C |
| Range: |
0 to 2000 μS/cm |
| Resolution: |
0.1 μS/cm |
|
Accuracy: |
± 1 μS/cm or ± 2.5 % of reading whichever is worse |
| Operating Temperature: |
0°C to 100°C * |
|
Contact Material: |
Peek (FDA compliant) |
|
IP Class: |
IP67 |
|
Temperature Sensor: |
Pt-1000 to provide automatic temperature compensation |
| Dimensions L x D: |
37 mm x 25 mm / 13 mm |
|
Immersion Depth: |
Minimum 25 mm |