jpgFeature/sdesk 696 implement raw brick http
Temperature from -100°C to +140°C

Temperature from -100°C to +140°C

Rental request

Validation equipment recommended for Mechanical Freezer, Refrigerator, Incubators, Waterbaths, Ware houses, Low-temp ovens

Wireless Data Loggers

Data Logger Option

A complete data logger kit could include the following: Frigo or Pro loggers depending on application, Laptop, Temperature Bath, Temperature Standard.

Ellab Frigo Loggers work well from -90°C to +85°C. We offer these for rent only with a rigid tip since they are only for open air environments.If you require product/item penetration then look at our TrackSense Pro units. Rigid probes requires the use of a liquid bath in order to perform calibrations/verifications.  If renting rigid probes Ellab will be able to perform the pre-calibration/verification and post-calibration/verification since it requires a liquid bath.

If you own a liquid bath, you can perform these verifications on your own. Ellab TrackSense Pro Temperature Loggers work from -80°C to 140°C.  We offer these with Rigid and Bendable probes.If renting Rigid units then the above application note applies.  If renting bendable units then they can be verified in our dry block temperature baths.  Either way we can still do the pre/post calibration/verification for you.

Data Logger Accessories

Magnet Clips: Makes for easy placement of your data logger (Not for autoclaved environments)

Silicone Gripper: Our silicone gripper slides over the logger providing a square outer shell which prevents the logger from rolling around.  It also has a loop for hanging the logger.  These can be placed inside of your autoclave.

 

Thermocouple Based

E-Val Pro

E-Val Pro

A complete thermocouple kit could include the following: E-Val Pro, Thermocouples, Laptop, Temperature Bath, Temperature Standard.

Ellab E-Val Pro: Thermocouple based unit

Option to use your own thermocouples, or purchase thermocouples ready to go from Ellab.

Verification Equipment recommendation

All of our hardware can connect to the laptop for automated pre and post calibration/verification.

Temperature Bath: Ellab RTC 159A Dry Block:This will get you down to -100°C in a dry environment. It also goes up to 155°C in case you need the higher range. You will still need to do your LN2 as a low point, but this dry bath would eliminate the need for you to create a dewar for your -80°C point (which people typically use crushed dry ice and alcohol)

Temperature Probe: Ellab ETS25:This will read from -196°C to 420°C with an accuracy of ±0.025°C

Optional: Ellab can pre-calibrate/verify the thermocouples for you, and upon return post-calibrate/verify those thermocouples and send you a report instead of you renting the hardware to do yourself.

Ellab Inc.
303 E 17th Ave, Suite 10, Denver CO 80203
Phone: +1-303-425-3370
Email: usa@ellab.com

Additional Locations:
New Hampshire - Texas

Follow Us @ Linkedin
Join Us @ Youtube
Contact Us Today
Newsletter Sign up
Sign Up Now

This website uses cookies to improve your experience. We'll assume you're ok with that, but you can opt-out if you wish.

Read more.
Close