jpgFeature/sdesk 696 implement raw brick http
Dry Block Calibrators

Dry Block Calibrators

Ellab offers a series of transportable Dry Block Calibrators for temperature calibrations between -100 to +425 °C (+700 °C option). A stable temperature profile is created using the controlled heating device, fitted with the sensors/probes that require calibration.

 

Contact Sales

Main features for Ellab Dry Block Calibrators:

✔ Intelligent recalibration information
✔ Intuitive, fast and user-friendly navigation
✔ Easy to carry around due to its light weight
✔ Functional carrying case for transportation (optional or included)
✔ Multi-hole insert kits covering the common sensor sizes
✔ High profile design and long lasting quality

All Dry Block calibrators feature portability, accuracy, speed and advanced documenting functions via the calibration software.

  • Wide temperature range: -100 to +425 °C (+700°C option)
  • The unique active dual-zone block ensures perfect temperature homogeneity in the insert, even when calibrating large or several sensors.
  • USB communication 
  • High speed heating and cooling times.

The series of Dry Block Calibrators consists of a main cabinet with easy access to all controls, connection options, power inlet, etc. 

The Dey Blocks are equipped with a solid handle for convenient and safe handling – a protective carrying case for transportation is also an option. The several different inserts were designed go deep into the temperature calibrator in order to ensure stable readings for the various sensors and probes.

The high stability throughout the entire calibration zone is achieved by using an advanced and intuitive menu-driven controller with active dual-zone heating technology, in which each heating zone is individually controlled to compensate for possible heat loss. 

PTC 155A Dry Block Calibrator

PTC 155A Dry Block Calibrator

Main features are:

  • Temperature range: -25 to +155 °C
  • Stability: ± 0.01 °C
  • Unique active dual-zone regulation ensures perfect temperature homogeneity in the calibration zone
  • VGA display for an easy overview of the calibration status
  • Light weight and mobile

Technical Specifications - PTC 155A Dry Block Calibrator

Temperature Range:

-25 to +155 °C

Environmental:

0 to +40 °C / 0 - 90% RH, non-condensing

Stability:

±0.01°C

Display Resolution:

1 °C / 0.1 °C / 0.01 °C

Insert Dimension:

25.8 x 150 mm

Ellab Insert Capacity:

12-18 sensors + ETS

Heating Time (min. to max.):

16 minutes

Cooling Time (max. to min.):

25 minutes

Communication:

USB 2.0

Power:

115 / 230 V 50-60 Hz

External Size:

362 x 171 x 363 mm

Weight:

10.3 kg

PTC 425A Dry Block Calibrator

PTC 425A Dry Block Calibrator

Main features are:

  • Temperature range: +33 to +425 °C
  • Stability: ± 0.02 °C
  • Unique active dual-zone regulation ensures perfect temperature homogeneity in the calibration zone
  • VGA display for an easy overview of the calibration status
  • Light weight and mobile

Technical Specifications - PTC 425A Dry Block Calibrator

Temperature Range:

+33 to +425 °C

Environmental:

0 to +40 °C / 0 - 90% RH, non-condensing

Stability:

± 0.02°C

Display Resolution:

1 °C /0.1 °C / 0.01 °C

Insert Dimension:

25.8 x 155 mm

Ellab Insert Capacity:

4-18 sensors +ETS

Heating Time (min. to max.):

7 minutes

Cooling Time (max. to min.):

24 minutes

Communication:

USB 2.0

Power:

115 / 230 V 50-60 Hz

External Size:

362 x 171 x 363 mm

Weight:

8.2 kg

RTC 156A Dry Block Calibrator

RTC 156A Dry Block Calibrator

Main features are:

  • Temperature range: -30 to +155 °C
  • Stability: ± 0.005 °C
  • Unique active dual-zone regulation ensures perfect temperature homogeneity in the calibration zone
  • VGA display for an easy overview of the calibration status
  • Light weight and mobile

 

Contact Sales

Technical Specifications - RTC 156A Dry Block Calibrator

Temperature Range:

-30 to +155 °C

Environmental:

0 to +40°C / 0 - 90% RH, non-condensing

Stability:

± 0.005 °C

Display Resolution:

1 °C / 0.1 °C / 0.01 °C / 0.001 °C

Insert Dimension:

29.7 x 150 mm

Ellab Insert Capacity:

20-24 sensors + ETS

Heating Time (min. to max.):

19 minutes

Cooling Time (max. to min.):

37 minutes

Communication:

USB 2.0

Power:

115 / 230 V 50-60 Hz

External Size:

362 x 171 x 363 mm

Weight:

10.5 kg

RTC 159A Dry Block Calibrator

RTC 159A Dry Block Calibrator

Main features are:

  • Temperature range: -100 to +155 °C
  • Stability: ± 0.03 °C
  • Unique active dual-zone regulation ensures perfect temperature homogeneity in the calibration zone
  • VGA display for an easy overview of the calibration status
  • Light weight and mobile

Technical Specifications - RTC 159A Dry Block Calibrator

Temperature Range:

-100 to +155 °C

Environmental:

0 to +40 °C / 0 - 90% RH, non-condensing

Stability:

±0.03°C

Display Resolution:

1 °C / 0.1 °C / 0.01 °C / 0.001 °C

Insert Dimension:

29.7 x 150 mm

Ellab Insert Capacity:

20-24 sensors + ETS

Heating Time (min. to max.):

26 minutes

Cooling Time (max. to min.):

175 minutes*

Communication:

USB 2.0

Power:

115 / 230 V 50-60 Hz

External Size:

531 x 169 x 432 mm

Weight:

15.2 kg

Follow Us @ Linkedin
Join Us @ Youtube
Contact Us Today