jpgFeature/sdesk 696 implement raw brick http
TrackSense Pro X Wireless Data Logger - Relative Humidity and Temperature Sensor (Stability)

TrackSense Pro X Wireless Data Logger - Relative Humidity and Temperature Sensor (Stability)

The superior quality wireless TrackSense® Pro X data loggers are made with high-end technology that allows for accurate and stable measurements when performing various thermal processes. The Pro X logger is highly versatile, but excels at low temperature applications.

The Relative Humidity and Temperature Sensor (Stability) has a temperature range of 0 to +90 °C with an unmatched accuracy of ±0.1 °C (in range 0 to +85 °C) and a Relative humidity range of 0 to 100% RH. It can be used for applications within the pharmaceutical industry, and is especially ideal to determine humidity levels during the validation of a warehouse or stability chambers.

The TrackSense® Pro X data loggers are configured with interchangeable sensors to measure temperature, relative humidity, CO2 pressure, and conductivity. The data loggers can easily be activated and read by the Multi reader station, and when combined with the Sky module, they provide real time data via wireless communication.

 

Contact Sales

Technical Specifications

Sensor with this logger configuration:

Relative Humidity and Temperature Sensor (Stability)*

RH Measuring Range (0 to +85 °C):

0 - 100%

Measuring Principle:

Capacitance Sensing / Electrical Resistance

Sensor Element:

Capacitance / Pt1000 

RH Accuracy at 25 °C non-condensing (10% to 90%):

± 2%

RH Resolution:

0.10 %

RH Response Time (63% in slowly moving air):

8 Seconds

Temperature Measuring Range:

0 to +90 °C

Temperature Accuracy:

+5 to +85 °C:

± 0.1 °C

Temperature Response Time:

T-63%:

6.5 Seconds

T-90%:

17 Seconds

Logger with this sensor configuration:

Pro X

Operating Temperature:

0 to +90 °C

House Material:

316 L Stainless Steel

Diameter:

25 mm

Length:

44 mm

Weight With Battery:

48 Grams

Memory Capacity:

60,000 Data Points / 30,000 Samples

Minimum Sample Rate:

1 Second

Maximum Sample Rate:

24 Hours

Maximum Start Delay:

14 Days

Intrinsically Safe: 

Ex II1GD Ex ia IIC T3 Ga,  -60°C ≤ Tamb ≤ +105°C 

Time Accuracy:

± 5 Seconds Per 24 Hours

Battery:

TSP Standard Battery

*With ValSuite versions prior to 5.X, these sensors will be listed as LAB sensors.

If equipment is used in ATEX environment, special conditions for safe use stated in ATEX certificates section 17 must be considered.

ValSuite™ Validation Software
ValSuite™ Validation Software

ValSuite™ Pro is an intuitive validation software which collects and presents validation data from all Ellab measuring devices. The software package is designed for Windows 10, 64 Bit. The software is developed according to GAMP principles. ValSuite™ is availabe in four versions:

  • ValSuite™
  • ValSuite™ Medical
  • ValSuite™ Plus
  • ValSuite™ Pro 
Learn more
Multi Reader Station for Data Loggers
Multi Reader Station for Data Loggers

The TrackSense Pro Multi Reader Station is engineered with flexibility and speed in mind. The station has 4 positions for loggers and is connected to the PC via USB. By using the USB port, power is supplied directly from your PC reducing the need for an external power source. Starting up and reading loggers can now be performed in seconds. 16 data loggers can be started or read simultaneously, saving time, especially when 160 data loggers have to be started for one study.

Learn more
Sky Module for Wireless Communication
Sky Module for Wireless Communication

The Sky module contains all the necessary components for wireless communication between the logger and the Sky Access Point. An external antenna is also available for more difficult transmission environments.

Learn more
Follow Us @ Linkedin
Join Us @ Youtube
Contact Us Today
Newsletter Sign up
Sign Up Now

This website uses cookies to improve your experience. We'll assume you're ok with that, but you can opt-out if you wish.

Read more.
Close