jpgFeature/sdesk 696 implement raw brick http

High-Precision Smart Thermocouple Sensors for Qualification & Validation of Thermal Processes

Ellab offers a wide range of pre-assembled Type-T Thermocouple sensors that are ideal for thermal validation processes. The 7-stranded high performance thermocouples cover a temperature range of -196 to +400 °C and are tightly connected to the fully sealed USB plug that is used in connection with the E-Val™ Pro Validation System. In addition to an excellent strain relief, they offer a complete elimination of measured errors e.g. from faulty soldering, screw terminals, or moisture.

Each USB connector is equipped with a Pt1000 cold junction compensation sensor that secures the maximum precision of <± 0.05 °C if supplied pre-calibrated. A built-in EEPROM allows the storing of calibration constants and the serial number of each thermocouple sensor. With the Ellab Feed-Through, up to 40 thermocouple sensors can be installed in autoclaves, dry heaters, lyophilizers, and other thermal processing equipment.

Contact Sales
Wired Temperature Sensor Type T
STC22-TF Thermocouple
  • -196 to +200 °C
  • USB plug for Calibration offsets
  • Standard or Pre-calibrated
Wired Temperature Sensor Type T
STC32-TF Thermocouple
  • -196 to +200 °C
  • USB plug for Calibration offsets
  • Standard or Pre-calibrated
Wired Temperature Sensor Type T
STC-KT 3 Strand Thermocouple
  • 0 to +260 °C
  • USB plug for Calibration offsets
  • Standard or Pre-calibrated
Wired Temperature Sensor Type T
STC-KT 7 Strand Thermocouple
  • 0 to +260 °C
  • USB plug for Calibration offsets
  • Standard or Pre-calibrated
Wired Temperature Sensor Type T
SSU-MM Thermocouple
  • -196 to +400 °C
  • USB plug for Calibration offsets
  • Standard or Pre-calibrated
Wired Temperature Sensor Type T
STC-AC Thermocouple
  • -67 to +400 °C
  • USB plug for Calibration offsets
  • Standard or Pre-calibrated
Wired Temperature Sensor Type T
SSA TS Thermocouple
  • -20 to +135 °C
  • USB plug for Calibration offsets
  • Standard or Pre-calibrated
Wired Temperature Sensor Type T
SSA TF Thermocouple
  • -50 to +135 °C
  • USB plug for Calibration offsets
  • Standard or Pre-calibrated
Wired Temperature Sensor Type T
SSV Thermocouple
  • -20 to +135 °C
  • USB plug for Calibration offsets
  • Standard or Pre-calibrated
Wired Temperature Sensor Type T
SSS Thermocouple
  • -20 to +135 °C
  • USB plug for Calibration offsets
  • Standard or Pre-calibrated
Wired Temperature Sensor Type T
SSR Thermocouple
  • -20 to +135 °C
  • USB plug for Calibration offsets
  • Standard or Pre-calibrated
Wired Temperature Sensor Type T
SD4 Thermocouple
  • -20 to +135 °C
  • USB plug for Calibration offsets
  • Standard or Pre-calibrated
ALFA LABORATORIES S.A.L, Lebanon

We have replaced our old cable system by Ellab Wireless dataloggers TrackSense® Pro with sky option for Eto Sterilization. This transition has given our company the possibility to collect live data in our Eto process. Further to this very important fact, we have been using the ValSuite™ software. The combination of the hardware and software has really improved the quality of our results, also in terms of time consuming. Our company is pleased with the way in which Ellab conducted themselves throughout our applications, they are experts and very professional. We will not hesitate to work with Ellab in the future and strongly recommend them to future customers.

ALFA LABORATORIES S.A.L, Lebanon

View all testimonials
Laurie Predom

"Ellab Validation Solutions! One of the finest, customer oriented team I have worked with, and the EVP equipment is stellar in the business! Harry Glendinning is an awesome Manager, making it happen! Working with them will move your projects to fruition."

Laurie Predom Senior Validation Engineer , LP Technical Services LLC, USA

View all testimonials
Follow Us @ Linkedin
Join Us @ Youtube
Contact Us Today
Newsletter Sign up
Sign Up Now