jpgFeature/sdesk 696 implement raw brick http
Ellab Temperature Standard (ETS)
Ellab Temperature Standard (ETS)

The traceable ETS allows for extremely accurate temperature measurements by converting resistance into temperature using its built-in algorithms.

The ETS is available in 3 different versions covering the temperature range of -196 to +420°C and includes a calibration certificate that is traceable to NPL.

When connected to the ValSuite software, the LiquiCal bath and ETS provide a perfect setup which is automatic. This saves time and allows for a convenient calibration.

Type Temperature Accuracy
ETS10 -80 to +250°C ±0.015/0.025°C
ETS20 -50 to+150°C ±0.02°C
ETS25 -196 to +420°C ±0.025°C
ETS10
ETS10

Main features are:

  • Temperature Range -80 to +250 °C
  • Accuracy: ±0.015 °C / ±0.025 °C
  • Separated electronics from heat zone
  • Robust and Versatile Design

ETS10 Technical Specifications

Temperature Range:

-80 to +250 °C

Accuracy - Includes Instrument, PRT and Drift: 

-50 to +150°C:

±0.015°C

Other temperatures:

±0.025°C

Measuring Sample Rate:

1 Sec.

Digital Filter:

0-10 Sec.

Resistance:

100 Ω

Sensor Response Time:

T63%:

33 Sec.

T90%:

45 Sec.

Overall Dimension:

ø16x475mm

Interface & Power Source:

USB

Sensor Material:

ANSI 316L

Dimension of Sensor:

ø6.35x305mm

Minimum Immersion Depth:

100mm

Environmental:

15 - 35°C / 0 - 90% RH, non-condensing

Calibration:

Traceable to NPL

Calibration Algoritms:

ITS-90

Recommended Calibration Interval:

12 months

Weight w / wo Display:

0.35 kg / 0.25 kg

Optional Display:

Display:

8 digits, 7 segments, green LED

Resolution:

0.001°C

Power Supply for "Stand-Alone" use:

9 Volt

ETS20
ETS20

Main features are:

  • Temperature Range -50 to +150 °C
  • Accuracy: ±0.020 °C
  • Separated electronics from heat zone
  • Robust and Versatile Design
ETS20 Technical Specifications

Temperature Range:

-50 to +150 °C

Accuracy - Includes Instrument, PRT and Drift: 

-50 to +150°C:

±0.020°C

Other temperatures:

NA

Measuring Sample Rate:

1 Sec.

Digital Filter:

0-10 Sec.

Resistance:

100 Ω

Sensor Response Time:

T63%:

33 Sec.

T90%:

45 Sec.

Overall Dimension:

ø16x475mm

Interface & Power Source:

USB

Sensor Material:

ANSI 316L

Dimension of Sensor:

ø6.35x305mm

Minimum Immersion Depth:

100mm

Environmental:

15 - 35°C / 0 - 90% RH, non-condensing

Calibration:

Traceable to NPL

Calibration Algoritms:

ITS-90

Recommended Calibration Interval:

12 months

Weight w / wo Display:

0.35 kg / 0.25 kg

Optional Display:

Display:

8 digits, 7 segments, green LED

Resolution:

0.001°C

Power Supply for "Stand-Alone" use:

9 Volt

ETS25
ETS25

Main features are:

  • Temperature Range -196 to +420 °C
  • Accuracy: ±0.025 °C
  • Separated electronics from heat zone
  • Robust and Versatile Design
ETS25 Technical Specifications

Temperature Range:

-196 to +420 °C

Accuracy - Includes Instrument, PRT and Drift: 

-50 to +150°C:

±0.025°C

Other temperatures:

±0.025°C

Measuring Sample Rate:

1 Sec.

Digital Filter:

0-10 Sec.

Resistance:

100 Ω

Sensor Response Time:

Overall Dimension:

ø16x475mm

T63%:

33 Sec.

T90%:

45 Sec.

Interface & Power Source:

USB

Sensor Material:

ANSI 316L

Dimension of Sensor:

ø6.35x305mm

Minimum Immersion Depth:

100mm

Environmental:

15 - 35°C / 0 - 90% RH, non-condensing

Calibration:

Traceable to NPL

Calibration Algoritms:

ITS-90

Recommended Calibration Interval:

12 months

Weight w / wo Display:

0.35 kg / 0.25 kg

Optional Display:

Display:

8 digits, 7 segments, green LED

Resolution:

0.001°C

Power Supply for "Stand-Alone" use:

9 Volt

Follow Us @ Linkedin
Join Us @ Youtube
Contact Us Today
Newsletter Sign up
Sign Up Now

This website uses cookies to improve your experience. We'll assume you're ok with that, but you can opt-out if you wish.

Read more.
Close